Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 2, 2018, 07:40 AM
  • 02 0847_02 0846_02052018_005250.mp4

Date
05/02/2018
W/O
696299
Weather
Dry
Operator/Surveyor
K. ADAME
Sewer ID
Z00296
PipeID
P03413
Time
12:40 AM
Certificate
U-0817-07009000
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5551
Sewer Name
02 OLD RIVER SCHOOL ROAD RELIEF TRUNK, SECTION 1
City
DOWNEY, CA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
26
Purpose
Routine Assessment
Project
WO_696299_TV02088_APR2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
27 in.
Upstream MH
02 0847
Downstream MH
02 0846
Dir. of Survey
Downstream
Length Surveyed
340.2 ft.
Total Length
340.2 ft.
Structural Index
1
Structural Quick
1100
Structural Rating
1
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
1
Overall Quick
Overall Rating
1
Pipe schematic from manhole 02 0847 to 02 0846
MH: 02 0847MH: 02 0846downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 08470 ft. MWL - Water Level, 35 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area6.1 ft. SRI - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: NO, Start6.1 ft. MGO - General Observation - MAG COAT337.5 ft. SRI - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish340.2 ft. AMH - Downstream Manhole, Survey Ends - 02 0846

Observation photos (2)

  • Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    6.1 ft. - Surface Roughness Increased, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • General Observation - MAG COAT

    6.1 ft. - General Observation - MAG COAT

Observations (7)

DistanceCodeObservation
0AMH02 0847
340.2AMH02 0846
6.1SRI
0MWL
6.1MGOMAG COAT
0MWM
337.5SRI

Properties (6)

additional_info
SC359156
custom_field_two
3
customer
LACSD
datetime
2018-05-02T00:40:11-07:00
documentation
PRO-PIPE
is_lateral_inspection
false