Section#1_F 0200_F 0199__792018__I0031.mp4
2 ft. - Material Change, Reinforced concrete pipe - START
2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - PEELING FLAKING CONCRETE
8 ft. - General Observation - POSSIBLE OLD MAG COAT ON PIPE
166 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - RUSTING FLAKING CONCRETE
262.9 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, - SEVERE AGG
275.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC
320.6 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO - PEELING CONCRETE
447.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES - PEELING CONCRETE
459.5 ft. - General Observation - ZOOM 45 '
| Distance | Code | Observation |
|---|---|---|
| 0 | MWL | — |
| 246.4 | TFC | STUB |
| 166 | SSS | RUSTING FLAKING CONCRETE |
| 262.9 | SAP | SEVERE AGG |
| 0 | AMH | 4:40AM |
| 376.9 | TFC | STUB |
| 2 | MMC | START |
| 0 | MWM | — |
| 506.5 | SSS | PEELING FLAKING CONCRETE |
| 233.5 | TF | OPEN |
| 459.5 | MGO | ZOOM 45 ' |
| 8 | MGO | POSSIBLE OLD MAG COAT ON PIPE |
| 447.2 | SSS | PEELING CONCRETE |
| 506.5 | SAP | SEVERE AGG SPORATIC |
| 2 | SSS | PEELING FLAKING CONCRETE |
| 506.9 | AMH | 5:40AM |
| 101.5 | TFC | STUB |
| 301.6 | TB | ACTIVE |
| 459 | DSZ | ROCK |
| 320.6 | SSS | PEELING CONCRETE |
| 0 | MGO | MH CONN 9:00 ACTIVE |
| 275.7 | SAP | SEVERE AGG SPORATIC |