Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 20, 2017, 07:13 AM
  • 02 1085_02 1084 _19122017_231410.mp4

Date
12/19/2017
W/O
679272
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00282
PipeID
P03659
Time
11:13 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5284
Sewer Name
02 MONTEBELLO DIVERSION TRUNK
City
MONTEBELLO
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
18
Purpose
Routine Assessment
Project
WO_679272_TV02212_JAN2018
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1085
Downstream MH
02 1084
Dir. of Survey
Downstream
Length Surveyed
336.5 ft.
Total Length
336.5 ft.
Structural Index
3
Structural Quick
583L
Structural Rating
370
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
370
Pipe schematic from manhole 02 1085 to 02 1084
MH: 02 1085MH: 02 1084downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 10850 ft. MWM - Water Mark, 15 %of cross sectional area2.7 ft. MGO - General Observation - MAG COAT2.8 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start2.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start12.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"34 ft. SRV - Surface Reinforcement Visible, at 09 o'clock, within 8 inches of joint: YES42.9 ft. SRV - Surface Reinforcement Visible, at 08 o'clock, within 8 inches of joint: YES44 ft. SRV - Surface Reinforcement Visible, at 08 o'clock, within 8 inches of joint: YES, Start61.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"66.8 ft. SRV - Surface Reinforcement Visible, at 08 o'clock, within 8 inches of joint: YES, Finish110.7 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"159.6 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"208.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"257 ft. SRV - Surface Reinforcement Visible, at 04 o'clock, within 8 inches of joint: YES265.2 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"314.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"334.8 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish334.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish336.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1084

Observation photos (6)

  • Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 09 o'clock, within 8 inches of joint: YES

    34 ft. - Surface Reinforcement Visible, at 09 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, at 08 o'clock, within 8 inches of joint: YES

    42.9 ft. - Surface Reinforcement Visible, at 08 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, at 08 o'clock, within 8 inches of joint: YES, Start

    44 ft. - Surface Reinforcement Visible, at 08 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 04 o'clock, within 8 inches of joint: YES

    257 ft. - Surface Reinforcement Visible, at 04 o'clock, within 8 inches of joint: YES

Observations (21)

DistanceCodeObservation
336.5AMH02 1084
2.8SAV
2.7MGOMAG COAT
257SRV
314.5TFC
0MWL
2.8SSS
110.7TFC
42.9SRV
334.8SAV
208.5TFC
265.2TFC
159.6TFC
334.8SSS
0AMH02 1085
34SRV
44SRV
12.8TFC
66.8SRV
61.6TFC
0MWM

Properties (6)

additional_info
SC346761
custom_field_two
2
customer
LACSD
datetime
2017-12-19T23:13:58-08:00
documentation
PROPIPE
is_lateral_inspection