Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 28, 2017, 10:02 AM
  • 02 1313_02 1312_28112017_020237.mp4

Date
11/28/2017
W/O
673943
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03833
Time
2:02 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5052
Sewer Name
02 BELVEDERE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_673943_TV02329_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1313
Downstream MH
02 1312
Dir. of Survey
Downstream
Length Surveyed
322.3 ft.
Total Length
322.3 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 02 1313 to 02 1312
MH: 02 1313MH: 02 1312downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13130 ft. MWM - Water Mark, 10 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area3.7 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start16.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"22 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"70.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"72.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"106.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"108.6 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"119.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"168 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"170.1 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"173.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"178.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"191.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"196.2 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"214.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"281.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"299.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"309.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"317 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"317.8 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish322.3 ft. MGO - General Observation - CAPPED LATERAL 3 O'CLOCK @ MH322.3 ft. AMH - Downstream Manhole, Survey Ends - 02 1312

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    3.7 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
170.1TB
108.6TB
75.4TFC
196.2TB
72.5TB
0AMH02 1313
309.3TB
191.2TFC
178.2TB
16.4TFC
173.1TFC
299.2TF
106.4TFC
22TB
214.2TF
317TFC
0MWM
70.4TFC
0MWL
281.3TF
317.8CM
119.2TF
168TFC
322.3MGOCAPPED LATERAL 3 O'CLOCK @ MH
322.3AMH02 1312
3.7CM

Properties (6)

additional_info
SC346281
custom_field_two
3
customer
LACSD
datetime
2017-11-28T02:02:13-08:00
documentation
PROPIPE
is_lateral_inspection
false