Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 28, 2017, 09:00 AM
  • 02 1324_02 2039 _28112017_010222.mp4

Date
11/28/2017
W/O
673943
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00238
PipeID
P03847
Time
1:00 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K5052
Sewer Name
02 BELVEDERE TRUNK
City
LOS ANGELES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
08
Purpose
Routine Assessment
Project
WO_673943_TV02329_DEC2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
02 1324
Downstream MH
02 2039
Dir. of Survey
Downstream
Length Surveyed
200.5 ft.
Total Length
200.5 ft.
Structural Index
3
Structural Quick
4A3B
Structural Rating
105
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
109
Pipe schematic from manhole 02 1324 to 02 2039
MH: 02 1324MH: 02 2039downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13245.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"8.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES13.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start18.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"31.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start51.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"64 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Start64 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish64 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish68 ft. MGO - General Observation - OUT OF ROUND, START74.4 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6" - CAPPED, BROKEN78.2 ft. B - Broken, from 12 to 02 o'clock, within 8 inches of joint: YES90 ft. MGO - General Observation - OUT OF ROUND, END94.8 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - FRACTURE109.5 ft. FM - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Finish167.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"171.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start185.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"189.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"200.5 ft. AMH - Downstream Manhole, Survey Ends - 02 2039200.5 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK200.5 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK200.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    8.2 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    13.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    31.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Start

    64 ft. - Fracture Multiple, from 08 to 03 o'clock, within 8 inches of joint: YES, Start

  • Broken, from 12 to 02 o'clock, within 8 inches of joint: YES

    78.2 ft. - Broken, from 12 to 02 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    171.5 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (26)

DistanceCodeObservation
5.4TF
200.5AMH02 2039
185.2TF
167.7TF
68MGOOUT OF ROUND, START
13.1CM
200.5MGOCONNECTION AT MH 12 O'CLOCK
189.3TF
74.4TFDCAPPED, BROKEN
51.3TF
18.4TFC
94.8TFDFRACTURE
78.2B
64FM
200.5MGOCONNECTION AT MH 9 O'CLOCK
64CM
0MWL
8.2CL
171.5CL
0MWM
200.5CL
0AMH02 1324
90MGOOUT OF ROUND, END
31.4FL
109.5FM
64FL

Properties (6)

additional_info
SC346281
custom_field_two
1
customer
LACSD
datetime
2017-11-28T01:00:15-08:00
documentation
PROPIPE
is_lateral_inspection
false