Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 9, 2018, 09:13 AM
  • Section#1_C 0102A_C 0102__192018__G6912.mp4

Date
01/09/2018
W/O
#
Weather
Heavy Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00123
PipeID
P09570
Time
1:13 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6912
Sewer Name
C JOINT OUTFALL C - UNIT 3D
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
24
Purpose
Capital Improvement Program Assesment
Project
20180109MDM_JOINT_OUTFALL_C_UNIT_3D
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Upstream MH
C 0102A
Downstream MH
C 0102
Dir. of Survey
Downstream
Length Surveyed
356.7 ft.
Total Length
356.7 ft.
Structural Index
3
Structural Quick
5F4M
Structural Rating
601
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
3
Overall Quick
Overall Rating
606
Pipe schematic from manhole C 0102A to C 0102
MH: C 0102AMH: C 0102downstream0 ft. MWM - Water Mark, 90 %of cross sectional area0 ft. MWL - Water Level, 70 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 1:30AM0 ft. MGO - General Observation - MH CONN 9:00 ACTIIVE VERY TURBLUENT EFFECT ON FLOW2 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG2 ft. SSS - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE2 ft. MGO - General Observation - MAG COAT 60% START11:00 TO 1:002.5 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE2.5 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE UNDER MAG COAT(16" X36")2.5 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE(16" X36"2.5 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE(16" X36")2.5 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE2.5 ft. SMW - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL UNDER MAG COAT3 ft. SMW - Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID3 ft. SMW - Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID3 ft. SMW - Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID17.4 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR CORRODED & MISSING24 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING89 ft. MGO - General Observation - MAG COAT 100% START143.7 ft. SRC - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish - CORRODED MISSING REBAR300.3 ft. MGO - General Observation - 100% MAG COAT356.2 ft. MGO - General Observation - MAG COAT 100% FINISH 11:00 TO 1:00356.2 ft. SAM - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG356.2 ft. MGO - General Observation - MH CONN OPEN 3:00356.2 ft. SSS - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish - BLISTERING CONCRETE356.2 ft. MGO - General Observation - MH CONN OPEN 9:00356.7 ft. AMH - Downstream Manhole, Survey Ends - 2:40AM

Observation photos (17)

  • Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE

    2 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - BLISTERING CONCRETE

  • General Observation - MAG COAT 60% START11:00 TO 1:00

    2 ft. - General Observation - MAG COAT 60% START11:00 TO 1:00

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE

    2.5 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE UNDER MAG COAT(16" X36")

    2.5 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE UNDER MAG COAT(16" X36")

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE(16" X36"

    2.5 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE(16" X36"

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE(16" X36")

    2.5 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE(16" X36")

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE

    2.5 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE

  • Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL UNDER MAG COAT

    2.5 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL UNDER MAG COAT

  • Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID

    3 ft. - Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID

  • Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID

    3 ft. - Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID

  • Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID

    3 ft. - Surface Missing Wall, from 12 to 01 o'clock, within 8 inches of joint: NO - VOID

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR CORRODED & MISSING

    17.4 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR CORRODED & MISSING

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING

    24 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING

  • General Observation - MAG COAT 100% START

    89 ft. - General Observation - MAG COAT 100% START

  • Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish - CORRODED MISSING REBAR

    143.7 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES, Finish - CORRODED MISSING REBAR

  • General Observation - 100% MAG COAT

    300.3 ft. - General Observation - 100% MAG COAT

Observations (27)

DistanceCodeObservation
356.2MGOMAG COAT 100% FINISH 11:00 TO 1:00
2.5SMWSOIL VISIBLE
2.5SMWSOIL VISIBLE UNDER MAG COAT(16" X36")
2SAMSEVERE AGG
24SRCCIRCUM REBAR MISSING
0MWM
89MGOMAG COAT 100% START
356.2SAMSEVERE AGG
2.5SMWSOIL VISIBLE(16" X36"
356.2MGOMH CONN OPEN 3:00
3SMWVOID
3SMWVOID
143.7SRCCORRODED MISSING REBAR
300.3MGO100% MAG COAT
0MWL
0AMH1:30AM
2.5SMWSOIL VISIBLE(16" X36")
3SMWVOID
2.5SMWSOIL VISIBLE
17.4SRCCIRCUM REBAR CORRODED & MISSING
0MGOMH CONN 9:00 ACTIIVE VERY TURBLUENT EFFECT ON FLOW
2SSSBLISTERING CONCRETE
356.2SSSBLISTERING CONCRETE
356.2MGOMH CONN OPEN 9:00
2.5SMWSOIL UNDER MAG COAT
356.7AMH2:40AM
2MGOMAG COAT 60% START11:00 TO 1:00

Properties (6)

custom_field_three
MISSING WALL SOIL VISIBLE & VOIDS
custom_field_two
1
customer
LACSD
datetime
2018-01-09T01:13:21-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false