Section#18_05 0337_05 0336__182018__G6908.mp4
0 ft. - Water Level, 5 %of cross sectional area - NO FLOW
3 ft. - Surface Spalling, from 11 to 01 o'clock, within 8 inches of joint: YES, - BLISTERING CONCRETE
3 ft. - Surface Aggregate Missing, from 11 to 01 o'clock, within 8 inches of joint: YES - SEVERE AGG
5.9 ft. - Surface Reinforcement Corroded, from 11 to 01 o'clock, within 8 inches of joint: YES - CIRCUM REBAR
8 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE-APPOX-(10" X3")
8 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
8 ft. - Surface Missing Wall, from 11 to 01 o'clock, within 8 inches of joint: NO - SOIL VISIBLE
9.9 ft. - Survey Abandoned - UPLEG DOWNSTREAM SIPHON SOUTH(1:30AM)
| Distance | Code | Observation |
|---|---|---|
| 3 | SSS | BLISTERING CONCRETE |
| 5.9 | SRC | CIRCUM REBAR |
| 0 | MWM | — |
| 8 | SMW | SOIL VISIBLE-APPOX-(10" X3") |
| 0 | AMH | 1:15AM |
| 8 | SMW | SOIL VISIBLE |
| 9.9 | MSA | UPLEG DOWNSTREAM SIPHON SOUTH(1:30AM) |
| 0 | MWL | NO FLOW |
| 8 | SMW | SOIL VISIBLE |
| 3 | SAM | SEVERE AGG |