Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 13, 2017, 10:41 AM
  • G 0054G 0053District 01_011317.mp4

Date
01/13/2017
W/O
613592
Weather
Damp
Operator/Surveyor
R.VARGAS
Sewer ID
Z00345
PipeID
P10417
Time
2:41 AM
Certificate
U-209-211
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4077
Sewer Name
G JOINT OUTFALL G - UNIT 5
City
COMPTON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
18
Purpose
Routine Assessment
Project
WO_613592_TV01215_JAN2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
G 0053
Downstream MH
G 0054
Dir. of Survey
Upstream
Length Surveyed
192.9 ft.
Total Length
192.9 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
2
O&M Quick
2G11
O&M Rating
77
Overall Index
2
Overall Quick
Overall Rating
80
Pipe schematic from manhole G 0053 to G 0054
MH: G 0053MH: G 0054upstream0 ft. AMH - Upstream Manhole, Survey Ends - G 00540 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE0 ft. VC - Vermin Cockroach2.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish2.9 ft. MGO - General Observation - MAGNEZIUM H.O. FINISH53.8 ft. LFW - Lining Failure Wrinkled, at 10 o'clock, within 8 inches of joint: YES190.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start190.8 ft. MGO - General Observation - MAGNESIUM H.O. START192.9 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED192.9 ft. AMH - Downstream Manhole, Survey Begins - G 0053192.9 ft. MGO - General Observation - LINER192.9 ft. MWM - Water Mark, 40 %of cross sectional area192.9 ft. MWL - Water Level, 30 %of cross sectional area192.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK ACTIVE

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Lining Failure Wrinkled, at 10 o'clock, within 8 inches of joint: YES

    139.1 ft. - Lining Failure Wrinkled, at 10 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
192.9AMHG 0054
2.1DAGS
0MGOCONNECTION AT MH 3 O'CLOCK CAPPED
190DAGS
190MGOMAGNEZIUM H.O. FINISH
0AMHG 0053
0MGOLINER
0MWM
192.9MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
0MWL
192.9VC
0MGOCONNECTION AT MH 9 O'CLOCK ACTIVE
2.1MGOMAGNESIUM H.O. START
139.1LFW

Properties (7)

additional_info
SC318618
custom_field_two
4
customer
LACSD
datetime
2017-01-13T02:41:13-08:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP