Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Oct 3, 2016, 09:18 AM
  • 01 0687_01 0686_03102016_021918.mp4

Date
10/03/2016
W/O
591536
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00199
PipeID
P01396
Time
2:18 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K3597
Sewer Name
01 CALIFORNIA AVENUE EXTENSION TRUNK
City
SOUTH GATE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
11
Purpose
Routine Assessment
Project
WO_591536_TV01117_SEP2016
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
33 in.
Upstream MH
01 0686
Downstream MH
01 0687
Dir. of Survey
Upstream
Length Surveyed
28.1 ft.
Total Length
28.2 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 01 0686 to 01 0687
MH: 01 0686MH: 01 0687upstream0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 01 068726 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start26.2 ft. MGO - General Observation - MAG COAT 70%28.2 ft. AMH - Downstream Manhole, Survey Begins - 01 068628.2 ft. MWL - Water Level, 15 %of cross sectional area28.2 ft. MWM - Water Mark, 25 %of cross sectional area

Observation photos (1)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0AMH01 0686
0MWL
28.2SAP
28.2AMH01 0687
2MGOMAG COAT 70%
0MWM
2.2SAP

Properties (6)

additional_info
SC306192
custom_field_two
3
customer
LACSD
datetime
2016-10-03T02:18:58-07:00
documentation
PROPIPE
is_lateral_inspection
false