Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 8, 2018, 10:26 AM
  • Section#6_18 0858_18 0857__582018__I0002.mp4

Date
05/08/2018
W/O
0701110
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00709
PipeID
P14713
Time
3:26 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
I0002
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
34
Purpose
Routine Assessment
Project
20180504MDM_SO_WHITTIER_OUTFALL_RLF_TR_SECTS_1_2A_2B_2C_3
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Upstream MH
18 0858
Downstream MH
18 0857
Dir. of Survey
Downstream
Length Surveyed
960.8 ft.
Total Length
960.8 ft.
Structural Index
3
Structural Quick
524A
Structural Rating
1029
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
1029
Pipe schematic from manhole 18 0858 to 18 0857
MH: 18 0858MH: 18 0857downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:35AM0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. MGO - General Observation - MAG COAT 70% START 9:00 TO 3:002 ft. SRV - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, - LONG REBAR2 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE42.9 ft. SAV - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC87.3 ft. SAV - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG177.9 ft. SAM - Surface Aggregate Missing, from 02 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG177.9 ft. SRV - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES, - CIRCUM REBAR184.8 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE225.4 ft. SAM - Surface Aggregate Missing, from 02 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERRE AGG473.1 ft. SAM - Surface Aggregate Missing, from 08 to 11 o'clock, within 8 inches of joint: YES - SEVERE AGG658 ft. SAM - Surface Aggregate Missing, from 09 to 11 o'clock, within 8 inches of joint: YES - SDEVERE AGG834.5 ft. SAV - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: YES - SEVERE AGG960.1 ft. SAV - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG SPORATIC960.1 ft. MGO - General Observation - MAG COAT 70% FINISH960.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE960.8 ft. AMH - Downstream Manhole, Survey Ends - 5:10AM

Observation photos (12)

  • General Observation - MAG COAT 70% START 9:00 TO 3:00

    2 ft. - General Observation - MAG COAT 70% START 9:00 TO 3:00

  • Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES,  - LONG REBAR

    2 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: YES, - LONG REBAR

  • Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

    2 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC

    42.9 ft. - Surface Aggregate Visible, from 01 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG VERY SPORATIC

  • Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    87.3 ft. - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Missing, from 02 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    177.9 ft. - Surface Aggregate Missing, from 02 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES,  - CIRCUM REBAR

    177.9 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: YES, - CIRCUM REBAR

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

    184.8 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO - BLISTERING PEELING CONCRETE

  • Surface Aggregate Missing, from 08 to 11 o'clock, within 8 inches of joint: YES - SEVERE AGG

    473.1 ft. - Surface Aggregate Missing, from 08 to 11 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Aggregate Missing, from 09 to 11 o'clock, within 8 inches of joint: YES - SDEVERE AGG

    658 ft. - Surface Aggregate Missing, from 09 to 11 o'clock, within 8 inches of joint: YES - SDEVERE AGG

  • Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: YES - SEVERE AGG

    834.5 ft. - Surface Aggregate Visible, from 09 to 11 o'clock, within 8 inches of joint: YES - SEVERE AGG

Observations (20)

DistanceCodeObservation
2MGOMAG COAT 70% START 9:00 TO 3:00
2SRVLONG REBAR
2SAVSEVERE AGG SPORATIC
0AMH3:35AM
42.9SAVSEVERE AGG VERY SPORATIC
960.1SAVSEVERE AGG SPORATIC
177.9SAMSEVERE AGG
960.1MGOMAG COAT 70% FINISH
225.4SAMSEVERRE AGG
0MWM
87.3SAVSEVERE AGG
960.8AMH5:10AM
184.8SSSBLISTERING PEELING CONCRETE
0MWL
473.1SAMSEVERE AGG
834.5SAVSEVERE AGG
960.1SSSBLISTERING PEELING CONCRETE
2SSSBLISTERING PEELING CONCRETE
658SAMSDEVERE AGG
177.9SRVCIRCUM REBAR

Properties (6)

custom_field_three
LONG & CIRCUM REBAR VISIBLE
custom_field_two
2
customer
LACSD
datetime
2018-05-08T03:26:10-07:00
documentation
MARTIN,MANANES,OLIVER 111
is_lateral_inspection
false