Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 5, 2018, 10:23 AM
  • Section#3_18 0862_18 0861__552018__G6998.mp4

Date
05/05/2018
W/O
0701110
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00709
PipeID
P14714
Time
3:23 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6998
Sewer Name
18 SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
NORWALK
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
34
Purpose
Capital Improvement Program Assesment
Project
20180504MDM_SO_WHITTIER_OUTFALL_RLF_TR_SECTS_1_2A_2B_2C_3
Material
Reinforced Concrete Pipe
Shape
Circular
Height
51 in.
Upstream MH
18 0862
Downstream MH
18 0861
Dir. of Survey
Downstream
Length Surveyed
786.9 ft.
Total Length
786.9 ft.
Structural Index
2
Structural Quick
514A
Structural Rating
395
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
395
Pipe schematic from manhole 18 0862 to 18 0861
MH: 18 0862MH: 18 0861downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:05AM0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. MGO - General Observation - MAG COAT 60% START 9:00 TO 3:002 ft. SAM - Surface Aggregate Missing, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG11.6 ft. SRV - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR39.3 ft. SAP - Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG56.5 ft. SAM - Surface Aggregate Missing, from 01 to 03 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG61.5 ft. SAP - Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG68.1 ft. MGO - General Observation - 80% MAG COAT START141.3 ft. SSS - Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE186.5 ft. SAV - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG220.9 ft. SAV - Surface Aggregate Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC441.4 ft. SAV - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG444.9 ft. SAV - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG482.4 ft. SAV - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG767.6 ft. SAP - Surface Aggregate Projecting, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG786.6 ft. MGO - General Observation - MAG COAT 80% FINISH786.6 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE786.9 ft. AMH - Downstream Manhole, Survey Ends - 5:05AM

Observation photos (12)

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • General Observation - MAG COAT 60% START 9:00 TO 3:00

    2 ft. - General Observation - MAG COAT 60% START 9:00 TO 3:00

  • Surface Aggregate Missing, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE  AGG

    2 ft. - Surface Aggregate Missing, from 01 to 03 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    11.6 ft. - Surface Reinforcement Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    39.3 ft. - Surface Aggregate Projecting, from 09 to 11 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • General Observation - 80% MAG COAT START

    68.1 ft. - General Observation - 80% MAG COAT START

  • Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

    141.3 ft. - Surface Spalling, from 02 to 03 o'clock, within 8 inches of joint: NO - BLISTERING CONCRETE

  • Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

    186.5 ft. - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

  • Surface Aggregate Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

    220.9 ft. - Surface Aggregate Visible, from 09 to 10 o'clock, within 8 inches of joint: NO - SEVERE AGG SPORATIC

  • Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    444.9 ft. - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

    482.4 ft. - Surface Aggregate Visible, from 02 to 03 o'clock, within 8 inches of joint: NO - SEVERE AGG

  • Surface Aggregate Projecting, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

    767.6 ft. - Surface Aggregate Projecting, from 02 to 03 o'clock, within 8 inches of joint: YES - SEVERE AGG

Observations (21)

DistanceCodeObservation
11.6SRVCIRCUM REBAR
786.9AMH5:05AM
56.5SAMSEVERE AGG
2SSSBLISTERING PEELING CONCRETE
786.6MGOMAG COAT 80% FINISH
767.6SAPSEVERE AGG
186.5SAVSEVERE AGG
2MGOMAG COAT 60% START 9:00 TO 3:00
444.9SAVSEVERE AGG
0AMH4:05AM
141.3SSSBLISTERING CONCRETE
39.3SAPSEVERE AGG
220.9SAVSEVERE AGG SPORATIC
68.1MGO80% MAG COAT START
0MWM
2SAMSEVERE AGG
482.4SAVSEVERE AGG
441.4SAVSEVERE AGG
786.6SSSBLISTERING PEELING CONCRETE
61.5SAPSEVERE AGG
0MWL

Properties (6)

custom_field_three
VISIBLE CIRCUM REBAR
custom_field_two
2
customer
LACSD
datetime
2018-05-05T03:23:00-07:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false