Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 3, 2018, 05:49 PM
  • A 0209_A 0208_532018_110036.mp4

Date
05/03/2018
W/O
0686843
Weather
Dry
Operator/Surveyor
SHADLER
Sewer ID
Z00323
PipeID
P08145
Time
10:49 AM
Certificate
U-415-06024035
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G7700
Sewer Name
A JOA-1A LOS COYOTES WRP INTERCEPTOR
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
29
Purpose
Routine Assessment
Project
20180503KS_JOA_1A_LOS_COYOTES_WRP_INTERCEPTOR
Material
Reinforced Concrete Pipe
Shape
Circular
Height
75 in.
Upstream MH
A 0209
Downstream MH
A 0208
Dir. of Survey
Downstream
Length Surveyed
464.8 ft.
Total Length
464.8 ft.
Structural Index
4
Structural Quick
5131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
8
Pipe schematic from manhole A 0209 to A 0208
MH: A 0209MH: A 0208downstream0 ft. AMH - Upstream Manhole, Survey Begins - 10:55 AM0.1 ft. MWM - Water Mark, 15 %of cross sectional area0.1 ft. MWL - Water Level, 10 %of cross sectional area2 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start173.9 ft. MGP - General Photograph341 ft. MGP - General Photograph432.2 ft. MGP - General Photograph459.1 ft. MGO - General Observation - Peeling & Flaking Throughout The Reach459.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish459.1 ft. MGO - General Observation - Grease Throughout The Reach (5%)459.1 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - 75% MAG459.1 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish464.8 ft. AMH - Downstream Manhole, Survey Ends - 11:53 AM

Observation photos (5)

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG

    2 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 75% MAG

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph

    173.9 ft. - General Photograph

  • General Photograph

    341 ft. - General Photograph

  • General Photograph

    432.2 ft. - General Photograph

Observations (15)

DistanceCodeObservation
173.9MGP
459.1MGOPeeling & Flaking Throughout The Reach
432.2MGP
459.1SAV
459.1MGOGrease Throughout The Reach (5%)
459.1SZ75% MAG
341MGP
2SZ75% MAG
0AMH10:55 AM
0.1MWM
459.1SRV
0.1MWL
464.8AMH11:53 AM
2SAV
2SRV

Properties (6)

custom_field_two
3
customer
LACSD
datetime
2018-05-03T10:49:08-07:00
documentation
SHADLER, FRANKLIN, BRAR, VENDRYES
is_lateral_inspection
false
year_laid
19780526