Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 7, 2018, 11:00 AM
  • J 0320_J 0319A_372018_033921.mp4

Date
03/07/2018
W/O
0684725
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00059
PipeID
P11563
Time
3:00 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H0768
Sewer Name
J JOINT OUTFALL J - UNIT 1G
City
PALO VERDES
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
10
Purpose
Routine Assessment
Project
20180307MDM_JOINT_OUTFALL_J_UNIT_1G
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
J 0320
Downstream MH
J 0319A
Dir. of Survey
Downstream
Length Surveyed
139.7 ft.
Total Length
139.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole J 0320 to J 0319A
MH: J 0320MH: J 0319Adownstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:40AM8 ft. MGO - General Observation - 18" VCP & CIPP8 ft. MGP - General Photograph - CIPP109 ft. MGO - General Observation - 18" VCP & CIPP139.1 ft. MGO - General Observation - Conn. @ Mh, 9 O' Clock. Active139.7 ft. AMH - Downstream Manhole, Survey Ends - 3:55AM

Observation photos (3)

  • General Observation - 18" VCP & CIPP

    8 ft. - General Observation - 18" VCP & CIPP

  • General Photograph - CIPP

    8 ft. - General Photograph - CIPP

  • General Observation - 18" VCP & CIPP

    109 ft. - General Observation - 18" VCP & CIPP

Observations (8)

DistanceCodeObservation
0MWL
0MWM
8MGO18" VCP & CIPP
139.1MGOConn. @ Mh, 9 O' Clock. Active
8MGPCIPP
0AMH3:40AM
109MGO18" VCP & CIPP
139.7AMH3:55AM

Properties (7)

custom_field_three
CIPP LINER GOOD CONDITION
custom_field_two
4
customer
LACSD
datetime
2018-03-07T03:00:27-08:00
documentation
MARTIN,MANANES,REVELES,OLIVER 111
is_lateral_inspection
false
lining
CIPP