- Date
- 01/19/2021
- W/O
- 865324
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00460
- PipeID
- P05782
- Time
- 2:30 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8424
- Sewer Name
- 05 INGLEWOOD TRUNK #2
- City
- INGLEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 02
- Purpose
- Routine Assessment
- Project
- WO_865324_TV05047_DEC2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 8 in.
- Width
- 10 in.
- Upstream MH
- 05 0562
- Downstream MH
- 05 0563
- Dir. of Survey
- Upstream
- Length Surveyed
- 310.1 ft.
- Total Length
- 310.1 ft.
- Structural Index
- 2
- Structural Quick
- 2600
- Structural Rating
- 12
- O&M Index
- 2
- O&M Quick
- 4132
- O&M Rating
- 151
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 163
Pipe schematic from manhole 05 0562 to 05 0563 Observation photos (6)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

68.7 ft. - Roots Fine Joint, from 12 to 04 o'clock, within 8 inches of joint: YESR - 10% ROOTS

115.3 ft. - Roots Ball Lateral, from 11 to 05 o'clock, 55 %, within 8 inches of joint: YES - 25% ROOTS

162 ft. - Roots Medium Lateral, from 12 to 04 o'clock, 25 %, within 8 inches of joint: YES

209.9 ft. - Roots Fine Barrell, from 12 to 07 o'clock, within 8 inches of joint: YES - 25% ROOTS

212.7 ft. - Roots Medium Lateral, from 06 to 12 o'clock, 20 %, within 8 inches of joint: YES