Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 15, 2021, 09:09 AM
  • F 0266_F 0265_01152021_013028.mp4

Date
01/15/2021
W/O
865005
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00040
PipeID
P10219
Time
1:09 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8423
Sewer Name
F JOINT OUTFALL F - UNIT 4 RELIEF
City
NORWALK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
37
Purpose
Routine Assessment
Project
WO_865005_TV02236_DEC2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
39 in.
Width
15 in.
Upstream MH
F 0266
Downstream MH
F 0265
Dir. of Survey
Downstream
Length Surveyed
585.8 ft.
Total Length
585.8 ft.
Structural Index
3
Structural Quick
3V2V
Structural Rating
580
O&M Index
2
O&M Quick
412X
O&M Rating
254
Overall Index
2
Overall Quick
Overall Rating
834
Pipe schematic from manhole F 0266 to F 0265
MH: F 0266MH: F 0265downstream0 ft. AMH - Upstream Manhole, Survey Begins - F 02660 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start539.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS584.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish584.2 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish584.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish584.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish585.8 ft. MGO - General Observation - COCKROACHES IN MANHOLE585.8 ft. AMH - Downstream Manhole, Survey Ends - F 0265

Observation photos (4)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    585.8 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (13)

DistanceCodeObservation
584.2SSS
539.2DSZDEBRIS
584.2SAP
585.8MGOCOCKROACHES IN MANHOLE
0AMHF 0266
585.8AMHF 0265
2SAP
584.2DAGS
2DAGS
584.2DSZ
2SSS
0MWM
0MWL

Properties (8)

additional_info
630069011421202
custom_field_three
SPALLING/PROJECTING AGGREGATE
custom_field_two
2
customer
1
datetime
2021-01-15T01:09:09-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
31219