Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 7, 2021, 11:46 AM
  • B 0698A_B 0698_01072021_035440.mp4

Date
01/07/2021
W/O
865130
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00110
PipeID
P09369
Time
3:46 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8408
Sewer Name
B JOINT OUTFALL B - UNIT 8G
City
DUARTE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_865130_TV22155_DEC2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
54 in.
Upstream MH
B 0698
Downstream MH
B 0698A
Dir. of Survey
Upstream
Length Surveyed
170.4 ft.
Total Length
170.4 ft.
Structural Index
3
Structural Quick
3D00
Structural Rating
78
O&M Index
2
O&M Quick
2F00
O&M Rating
66
Overall Index
2
Overall Quick
Overall Rating
144
Pipe schematic from manhole B 0698 to B 0698A
MH: B 0698MH: B 0698Aupstream0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - CONNECTION AT MH 12 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Ends - B 0698A1.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish19 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"27.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"37 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish109.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"112.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"164.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 5"165.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start168.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start170.4 ft. MWL - Water Level, 10 %of cross sectional area170.4 ft. MWM - Water Mark, 30 %of cross sectional area170.4 ft. MGO - General Observation - CONNECTION AT MH 10 O'CLOCK170.4 ft. AMH - Downstream Manhole, Survey Begins - B 0698170.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (3)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
0MWL
151.4TF
57.7TFA
2DAGS
0MWM
169DAGS
0MGOCONNECTION AT MH 10 O'CLOCK
5.9TFA
170.4MGOCOCKROACHES IN MANHOLE
61.1TFC
0AMHB 0698
5SAP
170.4MGOCONNECTION AT MH 12 O'CLOCK
0MGOCOCKROACHES IN MANHOLE
133.4SAP
142.5TFA
170.4AMHB 0698A

Properties (7)

additional_info
630069010621202
custom_field_three
PROJECTING AGGREGATE
custom_field_two
3
customer
1
datetime
2021-01-07T03:46:12-08:00
documentation
PRO PIPE
is_lateral_inspection
false