02 1888_02 1887_01112021_045208.mp4
2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start
2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start
81.9 ft. - Roots Fine Joint, at 12 o'clock, within 8 inches of joint: YESR
118.4 ft. - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES
148.9 ft. - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES
219.6 ft. - Survey Abandoned - REVERSAL COMPLETE. REMAINDER COMPLETED FROM U/S MH.
219.6 ft. - Repair Other Defective, within 8 inches of joint: YES - MISSHAPED
| Distance | Code | Observation |
|---|---|---|
| 81.9 | RFJ | — |
| 185.1 | TFA | — |
| 219.6 | MSA | REVERSAL COMPLETE. REMAINDER COMPLETED FROM U/S MH. |
| 148.9 | FL | — |
| 172.8 | TF | — |
| 0 | MWM | — |
| 0 | MGO | CONNECTION AT MH 8 O'CLOCK |
| 74.4 | TF | — |
| 2 | SAP | — |
| 0 | AMH | 02 1888 |
| 161.3 | TF | — |
| 59.1 | TF | — |
| 118.4 | FL | — |
| 2 | DAGS | — |
| 5.1 | TF | — |
| 115.7 | TFA | — |
| 31.7 | TFA | — |
| 7.9 | TFA | — |
| 219.6 | RPZD | MISSHAPED |
| 64.8 | TFA | — |
| 219.6 | SAP | — |
| 0 | MWL | — |
| 219.6 | DAGS | — |