- Date
- 01/22/2021
- W/O
- 087025
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00691
- PipeID
- P14343
- Time
- 12:35 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1702
- Sewer Name
- 18 NORTH PLANT OUTFALL TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210121MDM_NORTH_PLANT_OUTFALL_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Upstream MH
- 18 0489
- Downstream MH
- 18 0488
- Dir. of Survey
- Downstream
- Length Surveyed
- 295.4 ft.
- Total Length
- 295.4 ft.
- Structural Index
- 2
- Structural Quick
- 5141
- Structural Rating
- 83
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 83
Pipe schematic from manhole 18 0489 to 18 0488 Observation photos (5)

67.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

145.5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start - OUTER SURFACE CORRISON

242.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

295 ft. - Broken, from 03 to 06 o'clock, within 8 inches of joint: YES - WITH OF PIPE INTRUDING IN OUR LINE

295.4 ft. - Survey Abandoned - POSSIBLE BROKEN PIPE UNDER FLOW