- Date
- 01/20/2021
- W/O
- 0870813
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00215
- PipeID
- P00793
- Time
- 2:34 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1700
- Sewer Name
- 01 NADEAU TRUNK, SECTS 2&1
- City
- SOUTHGATE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 07
- Purpose
- Capital Improvement Program Assesment
- Project
- 20210120MDM_NADEAU_TRUNK_SECTS_2_1
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Upstream MH
- 01 0324
- Downstream MH
- 01 0325
- Dir. of Survey
- Upstream
- Length Surveyed
- 484.8 ft.
- Total Length
- 484.8 ft.
- Structural Index
- 3
- Structural Quick
- 3121
- Structural Rating
- 5
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 5
Pipe schematic from manhole 01 0324 to 01 0325 Observation photos (4)

0 ft. - General Observation - MAG COAT 100%

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE UNDER MAG COAT

171.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG SPORATIC

306.7 ft. - General Observation - 100% MAG COAT