Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 19, 2021, 08:30 AM
  • D 0212_05 1032_1192021_010424.mp4

Date
01/19/2021
W/O
0870119
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00424
PipeID
P06267
Time
12:30 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1689
Sewer Name
05 AVIATION BOULEVARD RELIEF TRUNK
City
MANHATTAN BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
20210119MDM_AVIATION_BOULEVARD_RELIEF_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Upstream MH
05 1032
Downstream MH
D 0212
Dir. of Survey
Upstream
Length Surveyed
9.8 ft.
Total Length
9.8 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 05 1032 to D 0212
MH: 05 1032MH: D 0212upstream0 ft. AMH - Upstream Manhole, Survey Ends - 1:50AM STOPLOG IN PLACE0.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE7.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE8.8 ft. DSZ - Deposits Settled Other, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - BOTTOM OF MH 10329.8 ft. AMH - Downstream Manhole, Survey Begins - 12:45AM9.8 ft. MWM - Water Mark, 20 %of cross sectional area9.8 ft. MWL - Water Level, 10 %of cross sectional area

Observation photos (4)

  • Deposits Settled Other,  30 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO - BOTTOM OF MH 1032

    1 ft. - Deposits Settled Other, 30 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO - BOTTOM OF MH 1032

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE

    9.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE

  • Upstream Manhole, Survey Ends - 1:50AM STOPLOG IN PLACE

    9.8 ft. - Upstream Manhole, Survey Ends - 1:50AM STOPLOG IN PLACE

Observations (7)

DistanceCodeObservation
0AMH12:45AM
0MWM
2SSSBLISTERING PEELING CONCRETE
0MWL
9.8AMH1:50AM STOPLOG IN PLACE
9.3SSSBLISTERING PEELING CONCRETE
1DSZBOTTOM OF MH 1032

Properties (7)

additional_info
REVERSE INSPECTION
custom_field_three
BLISTERING PEELING CONCRETE
custom_field_two
4
customer
LACSD
datetime
2021-01-19T00:30:32-08:00
documentation
MARTIN,OLIVER 111,CASTILLO,RUVALCABA
is_lateral_inspection