Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2021, 05:57 AM
  • D 0118_D 0117_01052021_220425.mp4

Date
01/05/2021
W/O
864852
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00156
PipeID
P10027
Time
9:57 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8348
Sewer Name
D JOINT OUTFALL D - UNIT 6
City
REDONDO BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_864852_TV05171_DEC2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
27 in.
Upstream MH
D 0118
Downstream MH
D 0117
Dir. of Survey
Downstream
Length Surveyed
87.2 ft.
Total Length
87.2 ft.
Structural Index
3
Structural Quick
3B2B
Structural Rating
85
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
85
Pipe schematic from manhole D 0118 to D 0117
MH: D 0118MH: D 0117downstream0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - D 01182.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. MGO - General Observation - 70% MAG COAT2.1 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start87.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish87.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish87.2 ft. AMH - Downstream Manhole, Survey Ends - D 0117

Observation photos (2)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
2.1SSS
87.2SAP
87.2SSS
0MWM
2.1MGO70% MAG COAT
2.1MGOCONN @ MH 3 O'CLOCK/ACTIVE
0MWL
2.1SAP
87.2AMHD 0117
0AMHD 0118

Properties (7)

additional_info
630075010521201
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2021-01-05T21:57:02-08:00
documentation
PROPIPE
is_lateral_inspection
false