Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2021, 09:43 AM
  • D 0108_D 0107_01062021_022557.mp4

Date
01/06/2021
W/O
864852
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00156
PipeID
P10014
Time
1:43 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8348
Sewer Name
D JOINT OUTFALL D - UNIT 6
City
LAWNDALE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_864852_TV05171_DEC2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
51 in.
Upstream MH
D 0108
Downstream MH
D 0107
Dir. of Survey
Downstream
Length Surveyed
535.9 ft.
Total Length
535.9 ft.
Structural Index
3
Structural Quick
3T2T
Structural Rating
535
O&M Index
2
O&M Quick
2T00
O&M Rating
212
Overall Index
2
Overall Quick
Overall Rating
747
Pipe schematic from manhole D 0108 to D 0107
MH: D 0108MH: D 0107downstream0 ft. MGO - General Observation - CONNE @ MH 9 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN0 ft. AMH - Upstream Manhole, Survey Begins - D 01080 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. MGO - General Observation - 65% MAG COAT2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start533 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish535.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish535.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish535.9 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE535.9 ft. AMH - Downstream Manhole, Survey Ends - D 0107535.9 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (2)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
0MGOCONNE @ MH 9 O'CLOCK/ACTIVE
0MWL
535.9SAP
2.1SSS
533DAGS
0MGOCONN @ MH 3 O'CLOCK/UNKNOWN
535.9SSS
535.9MGOCONN @ MH 9 O'CLOCK/ACTIVE
0AMHD 0108
2.1SAP
535.9AMHD 0107
2MGO65% MAG COAT
535.9MGOCONN @ MH 3 O'CLOCK/ACTIVE
2DAGS
0MWM

Properties (7)

additional_info
630075010521201
custom_field_three
AGGREGATE PROJECTING/SPALLING
custom_field_two
2
customer
1
datetime
2021-01-06T01:43:13-08:00
documentation
PROPIPE
is_lateral_inspection
false