Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2020, 08:28 AM
  • 01 0657_01 0656_12302020_005626.mp4

Date
12/30/2020
W/O
864828
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00212
PipeID
P01157
Time
12:28 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8360
Sewer Name
01 MOUNTAIN VIEW-BELLE VERNON TRUNK
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_864828_TV01110_DEC2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
01 0657
Downstream MH
01 0656
Dir. of Survey
Downstream
Length Surveyed
331.3 ft.
Total Length
331.3 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
195
O&M Index
3
O&M Quick
4137
O&M Rating
25
Overall Index
3
Overall Quick
Overall Rating
220
Pipe schematic from manhole 01 0657 to 01 0656
MH: 01 0657MH: 01 0656downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 06576.3 ft. CM - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES8.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start30.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"33.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"43.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"69.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"79.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"110.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"117.6 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"150.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"158 ft. RMC - Roots Medium Connection, from 02 to 04 o'clock, 15 %, within 8 inches of joint: YES159.1 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"159.1 ft. RBL - Roots Ball Lateral, from 12 to 12 o'clock, 90 %159.6 ft. RMJ - Roots Medium Joint, at 05 o'clock, 10 %, within 8 inches of joint: YESR162.5 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR, Start189.5 ft. RMJ - Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR, Finish189.5 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"199.9 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"227.7 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"238.4 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"268.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"307.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"310 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"328.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish331.3 ft. AMH - Downstream Manhole, Survey Ends - 01 0656

Observation photos (6)

  • Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

    6.3 ft. - Crack Multiple, from 07 to 05 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8.8 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Medium Connection, from 02 to 04 o'clock, 15 %, within 8 inches of joint: YES

    158 ft. - Roots Medium Connection, from 02 to 04 o'clock, 15 %, within 8 inches of joint: YES

  • Roots Ball Lateral, from 12 to 12 o'clock, 90 %

    159.1 ft. - Roots Ball Lateral, from 12 to 12 o'clock, 90 %

  • Roots Medium Joint, at 05 o'clock, 10 %, within 8 inches of joint: YESR

    159.6 ft. - Roots Medium Joint, at 05 o'clock, 10 %, within 8 inches of joint: YESR

  • Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR, Start

    162.5 ft. - Roots Medium Joint, from 07 to 05 o'clock, 10 %, within 8 inches of joint: YESR, Start

Observations (28)

DistanceCodeObservation
158RMC
159.6RMJ
69.3TF
8.8CM
6.3CM
307.2TF
79.6TF
0MWM
159.1TF
227.7TF
310TF
43.5TF
110.1TF
189.5RMJ
199.9TF
268.8TF
0MWL
328.5CM
117.6TF
162.5RMJ
159.1RBL
189.5TF
331.3AMH01 0656
238.4TF
30.5TF
33.2TF
0AMH01 0657
150.8TF

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-12-30T00:28:58-08:00
documentation
PRO PIPE
is_lateral_inspection
false