Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 31, 2020, 05:24 AM
  • 01 0647_01 0646_12302020_215151.mp4

Date
12/30/2020
W/O
864828
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00212
PipeID
P01146
Time
9:24 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8361
Sewer Name
01 MOUNTAIN VIEW-BELLE VERNON TRUNK
City
SOUTH GATE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_864828_TV01110_DEC2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
21 in.
Upstream MH
01 0647
Downstream MH
01 0646
Dir. of Survey
Downstream
Length Surveyed
369.8 ft.
Total Length
369.8 ft.
Structural Index
3
Structural Quick
3K00
Structural Rating
183
O&M Index
1
O&M Quick
1I00
O&M Rating
51
Overall Index
2
Overall Quick
Overall Rating
234
Pipe schematic from manhole 01 0647 to 01 0646
MH: 01 0647MH: 01 0646downstream0 ft. AMH - Upstream Manhole, Survey Begins - 01 06470 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start53.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"53.4 ft. RFL - Roots Fine Lateral, from 08 to 04 o'clock64.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start104.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"107 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"114.6 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"142.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"148.1 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 8"163.3 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"186.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"201.6 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"227.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"253.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish265.8 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"268.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"306.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"339.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"368.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish369.8 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK369.8 ft. AMH - Downstream Manhole, Survey Ends - 01 0646

Observation photos (4)

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Lateral, from 08 to 04 o'clock

    53.4 ft. - Roots Fine Lateral, from 08 to 04 o'clock

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    64.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

    114.6 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 8"

Observations (25)

DistanceCodeObservation
186.5TF
107TFA
369.8MGOCONNECTION AT MH, 3 O'CLOCK
163.3TF
2RFJ
265.8TF
142.7TFC
64.9CM
53.4TF
227.3TF
201.6TF
114.6TB
339.3TFC
253.4RFJ
0AMH01 0647
0MGOCONNECTION AT MH, 3 O'CLOCK
368.1CM
148.1TFA
104.4TF
369.8AMH01 0646
53.4RFL
0MWM
268.1TFC
306.1TFC
0MWL

Properties (6)

custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-12-30T21:24:43-08:00
documentation
PRO PIPE
is_lateral_inspection
false