Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 21, 2020, 07:55 AM
  • 01 0634_01 0633_5212020_010815.mp4

Date
05/21/2020
W/O
0829299
Weather
Dry
Operator/Surveyor
U-115-06022630
Sewer ID
Z00212
PipeID
P01130
Time
12:55 AM
Certificate
U-115-06022630
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1425
Sewer Name
01 MOUNTAIN VIEW-BELLE VERNON TRUNK
City
HUNTINGTON PARK
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
20200519VMR_MOUNTAIN_VIEW_BELLE_VERNON_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Upstream MH
01 0634
Downstream MH
01 0633
Dir. of Survey
Downstream
Length Surveyed
282.8 ft.
Total Length
282.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 01 0634 to 01 0633
MH: 01 0634MH: 01 0633downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01:02 AM0 ft. MWL - Water Level, 15 %of cross sectional area31.2 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"76.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"123.1 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"171.9 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"220.4 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: NO, 4"282.8 ft. AMH - Downstream Manhole, Survey Ends - 01:18 AM282.8 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 4"

Observations (10)

DistanceCodeObservation
171.9TF
282.8AMH01:18 AM
76.9TF
282.8TFC
0MWM
220.4TF
0AMH01:02 AM
0MWL
31.2TF
123.1TF

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2020-05-21T00:55:29-07:00
documentation
REVELES, OLIVER III, CASTILLO, SKINNER
is_lateral_inspection
false