Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 11, 2020, 08:12 AM
  • 05 0633_05 0632_12112020_002535.mp4

Date
12/11/2020
W/O
859962
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00509
PipeID
P05858
Time
12:12 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8329
Sewer Name
05 PRAIRIE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
05
Purpose
Routine Assessment
Project
WO_859962_TV05095_NOV2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
10 in.
Upstream MH
05 0633
Downstream MH
05 0632
Dir. of Survey
Downstream
Length Surveyed
527 ft.
Total Length
527 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 0633 to 05 0632
MH: 05 0633MH: 05 0632downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 06330 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - MAG COAT26.6 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 8"526.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish527 ft. AMH - Downstream Manhole, Survey Ends - 05 0632

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
527AMH05 0632
2.2SAV
0AMH05 0633
2.2MGOMAG COAT
0MWM
526.9SAV
0MWL
26.6TF

Properties (7)

additional_info
630075121020201
custom_field_three
AGREGATE VISIBLE
custom_field_two
3
customer
1
datetime
2020-12-11T00:12:36-08:00
documentation
PROPIPE
is_lateral_inspection
false