Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2020, 09:05 AM
  • 05 2205_05 2204_12142020_012348.mp4

Date
12/14/2020
W/O
859962
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00509
PipeID
P07352
Time
1:05 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8330
Sewer Name
05 PRAIRIE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Capital Improvement Program Assesment
Project
WO_859962_TV05095_NOV2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
15 in.
Upstream MH
05 2205
Downstream MH
05 2204
Dir. of Survey
Downstream
Length Surveyed
324.7 ft.
Total Length
324.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 05 2205 to 05 2204
MH: 05 2205MH: 05 2204downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 22050 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK capped2.1 ft. MMC - Material Change, Vitrified clay pipe - PIPE IS VCP2.1 ft. MGO - General Observation - MAG COAT7.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start324.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish324.7 ft. AMH - Downstream Manhole, Survey Ends - 05 2204

Observation photos (2)

  • Material Change, Vitrified clay pipe - PIPE IS VCP

    2.1 ft. - Material Change, Vitrified clay pipe - PIPE IS VCP

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start

    7.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
0MWM
0MWL
0AMH05 2205
324.7DAGS
324.7AMH05 2204
0MGOCONNECTION AT MH 3 O'CLOCK capped
2.1MMCPIPE IS VCP
2.1MGOMAG COAT
7.1DAGS

Properties (8)

additional_info
63009812142001
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2020-12-14T01:05:56-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26577