Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2020, 11:25 AM
  • 05 2202A_05 2202_12142020_033234.mp4

Date
12/14/2020
W/O
859962
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00509
PipeID
P07347
Time
3:25 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8330
Sewer Name
05 PRAIRIE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
WO_859962_TV05095_NOV2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
10 in.
Upstream MH
05 2202A
Downstream MH
05 2202
Dir. of Survey
Downstream
Length Surveyed
224.4 ft.
Total Length
224.4 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 2202A to 05 2202
MH: 05 2202AMH: 05 2202downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 2202A4.5 ft. MGO - General Observation - MAG COAT4.5 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start224.4 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish224.4 ft. AMH - Downstream Manhole, Survey Ends - 05 2202

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0MWL
4.5MGOMAG COAT
224.4SAV
224.4AMH05 2202
0MGOCONNECTION AT MH 3 O'CLOCK
0MWM
4.5SAV
0AMH05 2202A

Properties (8)

additional_info
63009812142001
custom_field_three
AGG.
custom_field_two
3
customer
1
datetime
2020-12-14T03:25:09-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26577