Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 15, 2020, 05:05 AM
  • 05 2198_05 2197_12142020_212347.mp4

Date
12/14/2020
W/O
859962
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00509
PipeID
P07342
Time
9:05 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8331
Sewer Name
05 PRAIRIE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
07
Purpose
Routine Assessment
Project
WO_859962_TV05095_NOV2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Width
10 in.
Upstream MH
05 2198
Downstream MH
05 2197
Dir. of Survey
Downstream
Length Surveyed
108.1 ft.
Total Length
108.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 05 2198 to 05 2197
MH: 05 2198MH: 05 2197downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 21980 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area2.1 ft. MGO - General Observation - MAG COAT56.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start108.1 ft. AMH - Downstream Manhole, Survey Ends - 05 2197108.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    56.7 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH05 2198
108.1AMH05 2197
56.7SAV
0MGOCONNECTION AT MH 9 O'CLOCK
2.1MGOMAG COAT
0MWL
108.1SAV
0MWM

Properties (8)

additional_info
630075121420201
custom_field_three
NO SEVERE DEFECTS
custom_field_two
3
customer
1
datetime
2020-12-14T21:05:49-08:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
26577