Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 1, 2017, 08:41 AM
  • 29 0316_29 0734 _01082017_014153.mp4

Date
08/01/2017
W/O
646910
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z01024
PipeID
P24332
Time
1:41 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4768
Sewer Name
29 PACIFIC COAST HIGHWAY TRUNK
City
SIGNAL HILL
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_646910_TV29082_JUL2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0734
Downstream MH
29 0316
Dir. of Survey
Upstream
Length Surveyed
337.9 ft.
Total Length
337.9 ft.
Structural Index
2
Structural Quick
2300
Structural Rating
6
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 29 0734 to 29 0316
MH: 29 0734MH: 29 0316upstream0 ft. AMH - Upstream Manhole, Survey Ends - 29 031611.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"23 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"26.6 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"28 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES36.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 04 o'clock, , within 8 inches of joint: YES53.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"55.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"99.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"102.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"150.8 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"153.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"201.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"206.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"245.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"250.4 ft. CS - Crack Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES254 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"274.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"333.6 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES337.9 ft. MWL - Water Level, 5 %of cross sectional area337.9 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK337.9 ft. MWM - Water Mark, 10 %of cross sectional area337.9 ft. AMH - Downstream Manhole, Survey Begins - 29 0734

Observation photos (5)

  • Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

    4.3 ft. - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES

    87.5 ft. - Crack Spiral, from 01 to 04 o'clock, within 8 inches of joint: YES

  • Deposits Attached Grease, 5 %of cross sectional area, from 07 to 04 o'clock,  , within 8 inches of joint: YES

    301.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 04 o'clock, , within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    309.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    311.3 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

Observations (23)

DistanceCodeObservation
284.2TFA
326.7TF
301.4DAGS
314.9TF
92.4TFC
311.3TB
0MWL
0MGOCONNECTION AT MH 9 O'CLOCK
235TF
63.2TF
83.9TF
0MWM
0AMH29 0734
187.1TFC
282.6TF
309.9CL
337.9AMH29 0316
184.5TF
238TF
136.6TFC
131TF
4.3CL
87.5CS

Properties (6)

additional_info
SC345528
custom_field_two
3
customer
LACSD
datetime
2017-08-01T01:41:23-07:00
documentation
PRO PIPE
is_lateral_inspection
false