Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 26, 2017, 10:39 AM
  • 29 0320_29 0319 _26072017_034141.mp4

Date
07/26/2017
W/O
646910
Weather
Dry
Operator/Surveyor
B. FUGATE
Sewer ID
Z01024
PipeID
P24337
Time
3:39 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K4763
Sewer Name
29 PACIFIC COAST HIGHWAY TRUNK
City
SIGNAL HILL
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 29
Page No.
04
Purpose
Routine Assessment
Project
WO_646910_TV29082_JUL2017
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
29 0320
Downstream MH
29 0319
Dir. of Survey
Downstream
Length Surveyed
337.5 ft.
Total Length
337.5 ft.
Structural Index
3
Structural Quick
3M25
Structural Rating
227
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
227
Pipe schematic from manhole 29 0320 to 29 0319
MH: 29 0320MH: 29 0319downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 29 03200 ft. MWM - Water Mark, 15 %of cross sectional area1.9 ft. MMC - Material Change, Concrete pipe (non-reinfored)1.9 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Start3 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES34.4 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES56.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES114.8 ft. CM - Crack Multiple, from 07 to 09 o'clock, within 8 inches of joint: YES119 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES121.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6"138.3 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES153.9 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES225.2 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6"260.3 ft. CL - Crack Longitudinal, at 08 o'clock, within 8 inches of joint: YES280.9 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES310.5 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: YES, 6"317.1 ft. FL - Fracture Longitudinal, at 08 o'clock, within 8 inches of joint: YES327.7 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES335.3 ft. SAV - Surface Aggregate Visible, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish337.5 ft. AMH - Downstream Manhole, Survey Ends - 29 0319

Observations (22)

DistanceCodeObservation
138.3CL
310.5TF
260.3CL
56.3FL
3CC
337.5AMH29 0319
0MWL
0MGOCONNECTION AT MH 3 O'CLOCK
280.9CL
119FL
1.9MMC
0AMH29 0320
0MWM
317.1FL
327.7CL
121.2TF
335.3SAV
225.2TF
114.8CM
153.9CM
1.9SAV
34.4CL

Properties (6)

additional_info
SC345523
custom_field_two
3
customer
LACSD
datetime
2017-07-26T03:39:53-07:00
documentation
PRO PIPE
is_lateral_inspection
false