Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 10, 2020, 08:46 AM
  • 14 0237_14 0236_12102020_005250.mp4

Date
12/10/2020
W/O
859953
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00575
PipeID
P18288
Time
12:46 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8272
Sewer Name
14 NORTH SIDE TRUNK
City
LANCASTER
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 14
Page No.
06
Purpose
Routine Assessment
Project
WO_859953_TV14067_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
14 0237
Downstream MH
14 0236
Dir. of Survey
Downstream
Length Surveyed
95 ft.
Total Length
95 ft.
Structural Index
3
Structural Quick
3B00
Structural Rating
51
O&M Index
2
O&M Quick
512C
O&M Rating
41
Overall Index
3
Overall Quick
Overall Rating
92
Pipe schematic from manhole 14 0237 to 14 0236
MH: 14 0237MH: 14 0236downstream0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. MWL - Water Level, 50 %of cross sectional area0 ft. MGO - General Observation - POSSIBLY A CONNECTION (ACTIVE) @ U/S MH - 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 14 02372 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start7.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start93 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Finish93 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish95 ft. MGO - General Observation - CAPPED CONNECTION @ 12 & 3 O'CLOCK - D/S MH95 ft. AMH - Downstream Manhole, Survey Ends - 14 0236

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    7.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWM
0MWL
0MGOPOSSIBLY A CONNECTION (ACTIVE) @ U/S MH - 9 O'CLOCK
7.2CM
2DAGS
93DAGS
93CM
95MGOCAPPED CONNECTION @ 12 & 3 O'CLOCK - D/S MH
95AMH14 0236
0AMH14 0237

Properties (7)

additional_info
630069120920202
custom_field_three
MULTIPLE CRACKS
custom_field_two
2
customer
1
datetime
2020-12-10T00:46:31-08:00
documentation
PRO PIPE
is_lateral_inspection
false