Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2021, 08:38 AM
  • 05 2148_05 2147_162021_021517.mp4

Date
01/06/2021
W/O
0872718
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00479
PipeID
P07297
Time
12:38 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1687
Sewer Name
05 MADISON STREET TRUNK
City
PALOS VERDES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
35
Purpose
Routine Assessment
Project
20210106MDM_MADISON_STREET_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
7.5 in.
Upstream MH
05 2148
Downstream MH
05 2147
Dir. of Survey
Downstream
Length Surveyed
349.6 ft.
Total Length
349.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
4122
O&M Rating
8
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 05 2148 to 05 2147
MH: 05 2148MH: 05 2147downstream0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:15AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active2 ft. DAGS - Deposits Attached Grease, 4 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Start8.1 ft. MGO - General Observation - 7.5" VCP-PVCP21.1 ft. TFD - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6", 6" - BROKEN PIPE-12:0089.7 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6" - Active136.8 ft. MGO - General Observation - 7.5" VCP - PVCP349.1 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active349.1 ft. DAGS - Deposits Attached Grease, 4 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Finish349.6 ft. AMH - Downstream Manhole, Survey Ends - 2:50AM

Observation photos (4)

  • Deposits Attached Grease, 4 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: NO, Start

    2 ft. - Deposits Attached Grease, 4 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: NO, Start

  • General Observation - 7.5" VCP-PVCP

    8.1 ft. - General Observation - 7.5" VCP-PVCP

  • Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6", 6" - BROKEN PIPE-12:00

    21.1 ft. - Tap Factory Made Defective, at 01 o'clock, -, within 8 inches of joint: NO, 6", 6" - BROKEN PIPE-12:00

  • General Observation - 7.5" VCP - PVCP

    136.8 ft. - General Observation - 7.5" VCP - PVCP

Observations (12)

DistanceCodeObservation
21.1TFDBROKEN PIPE-12:00
2DAGS
349.6AMH2:50AM
8.1MGO7.5" VCP-PVCP
349.1MGOConn. @ Mh, 3 O' Clock. Active
0MWM
0AMH2:15AM
0MWL
0MGOConn. @ Mh, 3 O' Clock. Active
136.8MGO7.5" VCP - PVCP
89.7TBAActive
349.1DAGS

Properties (7)

custom_field_three
LINER GOOD COND
custom_field_two
4
customer
LACSD
datetime
2021-01-06T00:38:09-08:00
documentation
MARTIN,CASTILLO,RUVALCABA
is_lateral_inspection
false
lining
PVCP