Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 25, 2015, 08:35 AM
  • 18 1057_18 1056_11252015_Manual.mp4

Date
11/25/2015
W/O
0541776
Weather
Light Rain
Operator/Surveyor
MARTIN
Sewer ID
Z00680
PipeID
P14912
Time
12:35 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
G6652
Sewer Name
18 LA HABRA HEIGHTS TRUNK, SECTION 3
City
LA HABRA HEIGHTS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
22
Purpose
Capital Improvement Program Assesment
Project
20151124MDM_LA_HABRA_HEIGHTS_TRUNK_SECTION_3
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
18 1057
Downstream MH
18 1056
Dir. of Survey
Downstream
Length Surveyed
247.9 ft.
Total Length
247.9 ft.
Structural Index
2
Structural Quick
332B
Structural Rating
37
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
37
Pipe schematic from manhole 18 1057 to 18 1056
MH: 18 1057MH: 18 1056downstream0 ft. AMH - Upstream Manhole, Survey Begins - 4:15AM0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area4.7 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - HAIRLINE6.2 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - HAIRLINE9.4 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT22 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB57.2 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SLIGHT75.4 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SLIGHT75.4 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - SLIGHT75.4 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE76.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB102.2 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - HAIRLINE102.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SLIGHT105.2 ft. FC - Fracture Circumferential, from 10 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE117.4 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - HAIRLINE123.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - HAIRLINE124.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE174.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB204 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - HAIRLINE209.9 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SLIGHT223 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - STUB224.5 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SLIGHT224.5 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT-VERY LONG227.3 ft. FC - Fracture Circumferential, from 12 to 02 o'clock, within 8 inches of joint: YES - HAIRLINE247.9 ft. AMH - Downstream Manhole, Survey Ends - 4:45AM

Observation photos (1)

  • Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT-VERY LONG

    224.5 ft. - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - SLIGHT-VERY LONG

Observations (26)

DistanceCodeObservation
117.4FLHAIRLINE
105.2FCHAIRLINE
22TFCSTUB
75.4FCSLIGHT
0AMH4:15AM
174.8TFCSTUB
224.5FCSLIGHT
209.9FCSLIGHT
75.4FCSLIGHT
227.3FCHAIRLINE
102.2FCHAIRLINE
223TFCSTUB
9.4FCSLIGHT
123.2FLHAIRLINE
102.2FCSLIGHT
0MWL
247.9AMH4:45AM
6.2FCHAIRLINE
124.2TFACTIVE
204FCHAIRLINE
224.5FCSLIGHT-VERY LONG
75.4FCHAIRLINE
0MWM
57.2FCSLIGHT
4.7FLHAIRLINE
76.3TFCSTUB

Properties (6)

custom_field_three
SLIGHT FRACTURES
custom_field_two
3
customer
LACSD
datetime
2015-11-25T00:35:27-08:00
documentation
MARTIN,MANANES,REVELES
is_lateral_inspection
false