Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 30, 2020, 05:27 AM
  • 05 0359_05 0358_12292020_222255.mp4

Date
12/29/2020
W/O
860153
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00432
PipeID
P05573
Time
9:27 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8341
Sewer Name
05 DISTRICT #5 MAIN RELIEF TRUNK
City
HAWTHORNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_860153_TV05325_NOV2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Width
36 in.
Upstream MH
05 0359
Downstream MH
05 0358
Dir. of Survey
Downstream
Length Surveyed
434.8 ft.
Total Length
434.8 ft.
Structural Index
3
Structural Quick
3O00
Structural Rating
243
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
243
Pipe schematic from manhole 05 0359 to 05 0358
MH: 05 0359MH: 05 0358downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 03590 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 30 %of cross sectional area2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.1 ft. MGO - General Observation - 75% MAG COAT77.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish434.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish434.8 ft. AMH - Downstream Manhole, Survey Ends - 05 0358

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (10)

DistanceCodeObservation
0MWM
2SAV
0AMH05 0359
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
434.7SAP
0MWL
3.1MGO75% MAG COAT
77.6SAV
2SAP
434.8AMH05 0358

Properties (7)

additional_info
630138122920201
custom_field_three
AGGRGGATE PROJECTING
custom_field_two
2
customer
1
datetime
2020-12-29T21:27:51-08:00
documentation
PROPIPE
is_lateral_inspection
false