Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 16, 2020, 06:22 AM
  • 05 1147_05 1146_12152020_223559.mp4

Date
12/15/2020
W/O
859967
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00436
PipeID
P06386
Time
10:22 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8332
Sewer Name
05 EAST ROSECRANS AVENUE TRUNK, SECTION 1
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
18
Purpose
Routine Assessment
Project
RFIR_WO_859967_TV05270_NOV2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
05 1147
Downstream MH
05 1146
Dir. of Survey
Downstream
Length Surveyed
334.8 ft.
Total Length
334.8 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
201
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
201
Pipe schematic from manhole 05 1147 to 05 1146
MH: 05 1147MH: 05 1146downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK capped0 ft. AMH - Upstream Manhole, Survey Begins - 05 11473.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.7 ft. CM - Crack Multiple, from 10 to 05 o'clock, within 8 inches of joint: YES65.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"116.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"182.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"315.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - ACTIVE334.8 ft. AMH - Downstream Manhole, Survey Ends - 05 1146334.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish334.8 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED334.8 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 10 to 05 o'clock, within 8 inches of joint: YES

    3.7 ft. - Crack Multiple, from 10 to 05 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
65.4TF
334.8AMH05 1146
315.2TFACTIVE
182.7TFC
0MGOACTIVE CONNECTION AT THE MH 3 OC'LOCK
3.7SAP
0MWM
334.8SAP
0MWL
255.1TFC
0MGOCONNECTION AT THE MH 9 OC'LOCK capped
116.5TFC
334.8MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
3.7CM
334.8MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
0AMH05 1147

Properties (7)

additional_info
630098121520201
custom_field_three
AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2020-12-15T22:22:36-08:00
documentation
PROPIPE
is_lateral_inspection
false