- Date
- 12/28/2020
- W/O
- 860202
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00152
- PipeID
- P09939
- Time
- 1:27 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K8336
- Sewer Name
- D JOINT OUTFALL D - UNIT 2B
- City
- GARDENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 24
- Purpose
- Routine Assessment
- Project
- WO_860202_TV05141_NOV2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Width
- 72 in.
- Upstream MH
- D 0040
- Downstream MH
- D 0039
- Dir. of Survey
- Downstream
- Length Surveyed
- 657 ft.
- Total Length
- 657 ft.
- Structural Index
- 3
- Structural Quick
- 3200
- Structural Rating
- 6
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole D 0040 to D 0039 Observation photos (2)

9.9 ft. - Lining Failure Pinhole, at 01 o'clock, within 8 inches of joint: NO

13.8 ft. - Lining Failure Pinhole, at 02 o'clock, within 8 inches of joint: NO