Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 28, 2020, 10:36 AM
  • D 0038_D 0037_12282020_025404.mp4

Date
12/28/2020
W/O
860202
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00152
PipeID
P09937
Time
2:36 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8336
Sewer Name
D JOINT OUTFALL D - UNIT 2B
City
GARDENA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
24
Purpose
Routine Assessment
Project
WO_860202_TV05141_NOV2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Width
72 in.
Upstream MH
D 0038
Downstream MH
D 0037
Dir. of Survey
Downstream
Length Surveyed
738.1 ft.
Total Length
738.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole D 0038 to D 0037
MH: D 0038MH: D 0037downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - D 00380 ft. MWM - Water Mark, 30 %of cross sectional area2.1 ft. MGO - General Observation - PIPE IS LINED738 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK738 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK738.1 ft. AMH - Downstream Manhole, Survey Ends - D 0037

Observations (7)

DistanceCodeObservation
0MWL
0AMHD 0038
738MGOCONNECTION AT MH, 9 O'CLOCK
0MWM
2.1MGOPIPE IS LINED
738MGOCONNECTION AT MH, 3 O'CLOCK
738.1AMHD 0037

Properties (9)

additional_info
630138122820001
custom_field_three
NO SEVERE DEFECTS
custom_field_two
4
customer
1
datetime
2020-12-28T02:36:02-08:00
documentation
PROPIPE
is_lateral_inspection
false
lining
FR POLY LINE
year_laid
35663