- Date
- 12/29/2020
- W/O
- 859976
- Weather
- Dry
- Operator/Surveyor
- b.fugate
- Sewer ID
- Z00499
- PipeID
- P05662
- Time
- 3:22 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8340
- Sewer Name
- 05 OAK STREET-CENTER AVENUE RELIEF TRUNK
- City
- INGLEWOOD
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 06
- Purpose
- Routine Assessment
- Project
- WO_859976_TV05188_NOV2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 22 in.
- Upstream MH
- 05 0449
- Downstream MH
- 05 0448
- Dir. of Survey
- Downstream
- Length Surveyed
- 368 ft.
- Total Length
- 368 ft.
- Structural Index
- 3
- Structural Quick
- 3N2N
- Structural Rating
- 365
- O&M Index
- 3
- O&M Quick
- 413L
- O&M Rating
- 205
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 570
Pipe schematic from manhole 05 0449 to 05 0448 Observation photos (3)

2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

31.3 ft. - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: NO, Start