Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 29, 2020, 09:55 AM
  • 03 0264_03 0263A_12292020_021156.mp4

Date
12/29/2020
W/O
860100
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00385
PipeID
P04866
Time
1:55 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8339
Sewer Name
03 MARKET STREET TRUNK
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
07
Purpose
Routine Assessment
Project
RFIR_WO_860100_TV03174_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
27 in.
Upstream MH
03 0264
Downstream MH
03 0263A
Dir. of Survey
Downstream
Length Surveyed
342.4 ft.
Total Length
342.4 ft.
Structural Index
3
Structural Quick
3M00
Structural Rating
204
O&M Index
2
O&M Quick
2600
O&M Rating
12
Overall Index
3
Overall Quick
Overall Rating
216
Pipe schematic from manhole 03 0264 to 03 0263A
MH: 03 0264MH: 03 0263Adownstream0 ft. AMH - Upstream Manhole, Survey Begins - 03 02640 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 5 %of cross sectional area3.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start30.6 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"98.6 ft. TFI - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"162.4 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"224.8 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"280.9 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1", 6"336.3 ft. TBI - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"342.4 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK342.4 ft. AMH - Downstream Manhole, Survey Ends - 03 0263A342.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (7)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    30.6 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    98.6 ft. - Tap Factory Made Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    162.4 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    224.8 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1", 6"

    280.9 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1", 6"

  • Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

    336.3 ft. - Tap Break-In Intruding, at 12 o'clock, -, -, within 8 inches of joint: NO, 6", 1"

Observations (13)

DistanceCodeObservation
3.1CM
342.4MGOCONNECTION AT MH, 9 O'CLOCK
280.9TBI
342.4AMH03 0263A
224.8TBI
30.6TBI
0AMH03 0264
0MWL
162.4TBI
342.4CM
98.6TFI
0MWM
336.3TBI

Properties (7)

additional_info
630138122820203
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-12-29T01:55:22-08:00
documentation
PROPIPE
is_lateral_inspection
false