- Date
- 12/08/2020
- W/O
- 859970
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z01181
- PipeID
- P17169
- Time
- 10:25 PM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K8238
- Sewer Name
- H JOINT OUTFALL H - UNIT 8K
- City
- COVINA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 24
- Purpose
- Routine Assessment
- Project
- WO_859970_TV22032_NOV2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 27 in.
- Width
- 27 in.
- Upstream MH
- H 1244
- Downstream MH
- H 1243
- Dir. of Survey
- Downstream
- Length Surveyed
- 141.5 ft.
- Total Length
- 141.5 ft.
- Structural Index
- 3
- Structural Quick
- 3E2E
- Structural Rating
- 140
- O&M Index
- 3
- O&M Quick
- 413E
- O&M Rating
- 88
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 228
Pipe schematic from manhole H 1244 to H 1243 Observation photos (4)

2.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.5 ft. - General Observation - MAG COAT

2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.5 ft. - Obstacles Rocks, 15 %of cross sectional area, at 06 o'clock, Start