Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 9, 2020, 09:49 AM
  • H 1234_H 1233_12092020_022523.mp4

Date
12/09/2020
W/O
859970
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01181
PipeID
P17159
Time
1:49 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8238
Sewer Name
H JOINT OUTFALL H - UNIT 8K
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
24
Purpose
Routine Assessment
Project
WO_859970_TV22032_NOV2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
H 1234
Downstream MH
H 1233
Dir. of Survey
Downstream
Length Surveyed
374.7 ft.
Total Length
374.7 ft.
Structural Index
3
Structural Quick
3N2N
Structural Rating
370
O&M Index
4
O&M Quick
4800
O&M Rating
32
Overall Index
3
Overall Quick
Overall Rating
402
Pipe schematic from manhole H 1234 to H 1233
MH: H 1234MH: H 1233downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 12342.9 ft. MGO - General Observation - MAG COAT2.9 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start27.7 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"36.3 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"67.7 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: YES, 8"75.6 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"122.5 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"130 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"146 ft. TF - Tap Factory Made, at 11 o'clock, -, within 8 inches of joint: YES, 8"169.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"216.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"232.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"248.1 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 8"295.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 8"336.2 ft. LR - Alignment Right, 25 %, Start374.7 ft. LR - Alignment Right, 25 %, Finish374.7 ft. MSA - Survey Abandoned - DUE TO TURN374.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish374.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (5)

  • General Observation - MAG COAT

    2.9 ft. - General Observation - MAG COAT

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Alignment Right, 25 %, Start

    336.2 ft. - Alignment Right, 25 %, Start

  • Survey Abandoned - DUE TO TURN

    374.7 ft. - Survey Abandoned - DUE TO TURN

Observations (23)

DistanceCodeObservation
374.7LR
2.9MGOMAG COAT
2.9SAP
0MWL
130TFC
0MWM
295.1TFC
0AMHH 1234
27.7TFC
374.7MSADUE TO TURN
67.7TF
248.1TFC
75.6TFC
336.2LR
146TF
2.9SSS
374.7SSS
216.1TFC
36.3TF
169.3TFC
374.7SAP
122.5TFC
232.1TFC

Properties (6)

custom_field_three
AGGREGATE PROJECTING
custom_field_two
3
customer
1
datetime
2020-12-09T01:49:27-08:00
documentation
PRO PIPE
is_lateral_inspection
false