Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 24, 2020, 08:44 AM
  • C 0565_C 0564_12242020_013818.mp4

Date
12/24/2020
W/O
860133
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00362
PipeID
P04749
Time
12:44 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8089
Sewer Name
C JOINT OUTFALL C - UNIT 4D
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
08
Purpose
Routine Assessment
Project
RFIR_WO_860133_TV03084_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
10 in.
Upstream MH
C 0565
Downstream MH
C 0564
Dir. of Survey
Downstream
Length Surveyed
419.5 ft.
Total Length
419.5 ft.
Structural Index
3
Structural Quick
3G00
Structural Rating
117
O&M Index
2
O&M Quick
412P
O&M Rating
170
Overall Index
2
Overall Quick
Overall Rating
287
Pipe schematic from manhole C 0565 to C 0564
MH: C 0565MH: C 0564downstream0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - C 05652 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start212.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start409.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish416 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish419.5 ft. AMH - Downstream Manhole, Survey Ends - C 0564

Observation photos (1)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    212.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
419.5AMHC 0564
2DAGS
409.2FL
0MWM
212.2FL
0MWL
416DAGS
0AMHC 0565

Properties (7)

additional_info
630098122320201
custom_field_three
LONGITUDINAL FRACTURE
custom_field_two
3
customer
1
datetime
2020-12-24T00:44:00-08:00
documentation
PRO PIPE
is_lateral_inspection
false