Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 15, 2020, 05:32 AM
  • 02 0110_02 0109_12142020_215608.mp4

Date
12/14/2020
W/O
860132
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00237
PipeID
P02277
Time
9:32 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8280
Sewer Name
02 BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_860132_TV02350_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
27 in.
Upstream MH
02 0110
Downstream MH
02 0109
Dir. of Survey
Downstream
Length Surveyed
334.3 ft.
Total Length
334.3 ft.
Structural Index
3
Structural Quick
433L
Structural Rating
201
O&M Index
2
O&M Quick
4131
O&M Rating
121
Overall Index
3
Overall Quick
Overall Rating
322
Pipe schematic from manhole 02 0110 to 02 0109
MH: 02 0110MH: 02 0109downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 01100 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK8.6 ft. FM - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES17.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start48.2 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS73 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"87.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"96.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"122.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"146.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"173.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"184.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"199.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"219.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6" - connection not capped240.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"266.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - Connection not capped277.1 ft. DAGS - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES278.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"292.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"329.5 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start333.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish333.3 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish333.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish334.3 ft. AMH - Downstream Manhole, Survey Ends - 02 0109334.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK334.3 ft. MGO - General Observation - COCKROACHES IN MANHOLE

Observation photos (6)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

    8.6 ft. - Fracture Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    17.2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 15 %of cross sectional area, from 08 to 10 o'clock,  , within 8 inches of joint: YES

    277.1 ft. - Deposits Attached Grease, 15 %of cross sectional area, from 08 to 10 o'clock, , within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    329.5 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    334.3 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (29)

DistanceCodeObservation
329.5FM
146.3TFC
0AMH02 0110
73TF
334.3AMH02 0109
8.6FM
333.3CM
0MWM
0MWL
292.7TF
173.1TFA
122.6TFC
199.6TFC
48.2DSZDEBRIS
184.6TFC
87.2TFA
240.4TFC
17.2CM
219.5TFconnection not capped
277.1DAGS
278.5TFA
333.3DSZ
96.6TFA
0MGOCOCKROACHES IN MANHOLE
0MGOCONNECTION AT MH 9 O'CLOCK
266.6TFConnection not capped
334.3MGOCONNECTION AT MH 3 O'CLOCK
334.3MGOCOCKROACHES IN MANHOLE
333.3FM