Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 15, 2020, 06:21 AM
  • 02 0108_02 0107_12142020_225641.mp4

Date
12/14/2020
W/O
860132
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00237
PipeID
P02275
Time
10:21 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8280
Sewer Name
02 BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
38
Purpose
Routine Assessment
Project
RFIR_WO_860132_TV02350_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
10 in.
Width
36 in.
Upstream MH
02 0108
Downstream MH
02 0107
Dir. of Survey
Downstream
Length Surveyed
366.1 ft.
Total Length
366.1 ft.
Structural Index
3
Structural Quick
3N00
Structural Rating
222
O&M Index
2
O&M Quick
413E
O&M Rating
240
Overall Index
3
Overall Quick
Overall Rating
462
Pipe schematic from manhole 02 0108 to 02 0107
MH: 02 0108MH: 02 0107downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 01080 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MANHOLE2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start20.9 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"59.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"86.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"110.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"121 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"172.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"175.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"191.7 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS UNDER WATER231.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES233.6 ft. MWL - Water Level, 50 %of cross sectional area234.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"237.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"249.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"276.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"321.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"339.4 ft. DSZ - Deposits Settled Other, 15 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish349.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"351.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6"365.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish365.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish366.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE366.1 ft. AMH - Downstream Manhole, Survey Ends - 02 0107366.1 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observation photos (5)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    231.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • General Observation - COCKROACHES IN MANHOLE

    366.1 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (30)

DistanceCodeObservation
276.1TFA
321.7TFA
175.4TFA
366.1MGOCOCKROACHES IN MANHOLE
366.1AMH02 0107
349.5TFC
365.1CM
0MWL
234.7TFA
59.5TF
110.9TFA
2CM
249.4TFA
0AMH02 0108
0MGOCONNECTION AT MH 3 O'CLOCK
237.5TFA
86.4TFA
231.2FL
0MWM
0MGOCOCKROACHES IN MANHOLE
339.4DSZ
233.6MWL
2DAGS
365.1DAGS
191.7DSZDEBRIS UNDER WATER
351.4TFA
20.9TBA
366.1MGOCONNECTION AT MH 9 O'CLOCK
121TFA
172.2TFC

Properties (7)

additional_info
630069121420201
custom_field_three
MULTIPLE CRACKS/FRACTURES/DEBRIS
custom_field_two
2
customer
1
datetime
2020-12-14T22:21:57-08:00
documentation
PRO PIPE
is_lateral_inspection
false