Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2020, 04:09 PM
  • 22 0751_22 0750_12182020_083342.mp4

Date
12/18/2020
W/O
859980
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00821
PipeID
P17108
Time
8:09 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K8081
Sewer Name
22 PUDDINGSTONE TRUNK, SECTS 1&2
City
SAN DIMAS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
23
Purpose
Routine Assessment
Project
WO_859980_TV22057_NOV2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0751
Downstream MH
22 0750
Dir. of Survey
Downstream
Length Surveyed
349.2 ft.
Total Length
349.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2M00
O&M Rating
138
Overall Index
2
Overall Quick
Overall Rating
138
Pipe schematic from manhole 22 0751 to 22 0750
MH: 22 0751MH: 22 0750downstream0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 07510 ft. MWM - Water Mark, 40 %of cross sectional area1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. MGO - General Observation - M.H.O COATING START45.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"97.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"149.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"197.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"245.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"296.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"340.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"346.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish346.8 ft. MGO - General Observation - M.H.O.COATIN END349.2 ft. AMH - Downstream Manhole, Survey Ends - 22 0750

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

Observations (15)

DistanceCodeObservation
2MGOM.H.O COATING START
1DAGS
245.2TFC
349.2AMH22 0750
296.7TFC
197.2TFC
0MWL
346.8DAGS
340.6TFC
0AMH22 0751
45.7TFC
97.5TFC
149.4TFC
0MWM
346.8MGOM.H.O.COATIN END

Properties (6)

custom_field_three
LIGHT GREASE
custom_field_two
3
customer
1
datetime
2020-12-18T08:09:20-08:00
documentation
PROPIPE
is_lateral_inspection
false