Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2020, 05:41 AM
  • 02 0164_02 0163_12172020_215857.mp4

Date
12/17/2020
W/O
860135
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00251
PipeID
P02467
Time
9:41 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8289
Sewer Name
02 DOWNEY-BELLFLOWER TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_860135_TV02327_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
24 in.
Upstream MH
02 0164
Downstream MH
02 0163
Dir. of Survey
Downstream
Length Surveyed
331.2 ft.
Total Length
331.2 ft.
Structural Index
2
Structural Quick
2I00
Structural Rating
102
O&M Index
2
O&M Quick
2T00
O&M Rating
208
Overall Index
2
Overall Quick
Overall Rating
310
Pipe schematic from manhole 02 0164 to 02 0163
MH: 02 0164MH: 02 0163downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 02 01640 ft. MWL - Water Level, 35 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start25.1 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start103.5 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"106.6 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: NO, 6"132.6 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start - DEBRIS158.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"161.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"216.5 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: NO, 6"218.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"245.9 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: NO, 6"264.5 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish309.9 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start324.2 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish329.1 ft. MGO - General Observation - COCKROACHES IN MANHOLE329.1 ft. DSZ - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish329.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish331.2 ft. AMH - Downstream Manhole, Survey Ends - 02 0163

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    25.1 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

    309.9 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    329.1 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (21)

DistanceCodeObservation
324.2CL
216.5TFA
218.5TFA
0MWM
132.6DSZDEBRIS
158.2TFC
331.2AMH02 0163
103.5TFA
25.1CL
161.4TFC
329.1MGOCOCKROACHES IN MANHOLE
0MGOCONNECTION AT MH 9 O'CLOCK
264.5CL
245.9TFC
106.6TFA
2DAGS
0AMH02 0164
309.9CL
329.1DSZ
0MWL
329.1DAGS

Properties (7)

additional_info
630069121720201
custom_field_three
LONGITUDINAL CRACK
custom_field_two
3
customer
1
datetime
2020-12-17T21:41:28-08:00
documentation
PRO PIPE
is_lateral_inspection
false