Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 16, 2020, 10:11 AM
  • 02 1349_02 1348_12162020_023814.mp4

Date
12/16/2020
W/O
860134
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00277
PipeID
P04623
Time
2:11 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8287
Sewer Name
02 JANE STREET BRANCH TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_860134_TV02342_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
02 1349
Downstream MH
02 1348
Dir. of Survey
Downstream
Length Surveyed
743.1 ft.
Total Length
743.1 ft.
Structural Index
3
Structural Quick
3V23
Structural Rating
354
O&M Index
2
O&M Quick
2]00
O&M Rating
296
Overall Index
2
Overall Quick
Overall Rating
650
Pipe schematic from manhole 02 1349 to 02 1348
MH: 02 1349MH: 02 1348downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MGO - General Observation - COCKROACHES IN MANHOLE0 ft. AMH - Upstream Manhole, Survey Begins - 02 13492 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start17.3 ft. MWL - Water Level, 10 %of cross sectional area126.5 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES137.3 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start149.1 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Finish161 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start289.3 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"565.7 ft. RPZ - Repair Other, within 8 inches of joint: YES - PATCHED CONNECTION574.8 ft. RPZ - Repair Other, within 8 inches of joint: YES - LINK PIPE741.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish741.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE741.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish743.1 ft. AMH - Downstream Manhole, Survey Ends - 02 1348

Observation photos (8)

  • General Observation - COCKROACHES IN MANHOLE

    0 ft. - General Observation - COCKROACHES IN MANHOLE

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

    126.5 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start

    137.3 ft. - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    161 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Repair Other, within 8 inches of joint: YES - PATCHED CONNECTION

    565.7 ft. - Repair Other, within 8 inches of joint: YES - PATCHED CONNECTION

  • Repair Other, within 8 inches of joint: YES - LINK PIPE

    574.8 ft. - Repair Other, within 8 inches of joint: YES - LINK PIPE

  • General Observation - COCKROACHES IN MANHOLE

    741.4 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (18)

DistanceCodeObservation
574.8RPZLINK PIPE
743.1AMH02 1348
149.1CL
741.4CM
289.3TBA
2DAGS
161CM
741.4MGOCOCKROACHES IN MANHOLE
0MWM
17.3MWL
126.5CL
741.4DAGS
0MWL
565.7RPZPATCHED CONNECTION
0MGOCONNECTION AT MH 9 O'CLOCK
0MGOCOCKROACHES IN MANHOLE
137.3CL
0AMH02 1349

Properties (7)

additional_info
630069121520204
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-12-16T02:11:41-08:00
documentation
PRO PIPE
is_lateral_inspection
false