Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 16, 2020, 11:00 AM
  • 02 1348_02 1347_12162020_031205.mp4

Date
12/16/2020
W/O
860134
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00277
PipeID
P04622
Time
3:00 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8287
Sewer Name
02 JANE STREET BRANCH TRUNK
City
COMMERCE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_860134_TV02342_NOV2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
02 1348
Downstream MH
02 1347
Dir. of Survey
Downstream
Length Surveyed
331.4 ft.
Total Length
331.4 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
198
O&M Index
2
O&M Quick
2L00
O&M Rating
132
Overall Index
3
Overall Quick
Overall Rating
330
Pipe schematic from manhole 02 1348 to 02 1347
MH: 02 1348MH: 02 1347downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13480 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start330.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish330.2 ft. MGO - General Observation - CONNECTION AT MH 7 O'CLOCK330.2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish331.4 ft. MGO - General Observation - COCKROACHES IN MANHOLE331.4 ft. AMH - Downstream Manhole, Survey Ends - 02 1347

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MANHOLE

    331.4 ft. - General Observation - COCKROACHES IN MANHOLE

Observations (10)

DistanceCodeObservation
331.4MGOCOCKROACHES IN MANHOLE
331.4AMH02 1347
0AMH02 1348
0MWM
2DAGS
0MWL
330.2CM
330.2MGOCONNECTION AT MH 7 O'CLOCK
330.2DAGS
2CM

Properties (7)

additional_info
630069121520204
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-12-16T03:00:40-08:00
documentation
PRO PIPE
is_lateral_inspection
false