Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 18, 2020, 10:32 AM
  • 02 0965_02 0964_12182020_024255.mp4

Date
12/18/2020
W/O
860497
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00279
PipeID
P03535
Time
2:32 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K8290
Sewer Name
02 MONTEBELLO TRUNK
City
COMMERCE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
20
Purpose
Routine Assessment
Project
WO_860497_TV02090_NOV2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
21 in.
Width
27 in.
Upstream MH
02 0964
Downstream MH
02 0965
Dir. of Survey
Upstream
Length Surveyed
380.7 ft.
Total Length
380.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2N00
O&M Rating
150
Overall Index
2
Overall Quick
Overall Rating
150
Pipe schematic from manhole 02 0964 to 02 0965
MH: 02 0964MH: 02 0965upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 09651.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Finish378.7 ft. MLC - Lining Change, Cured in place378.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start380.7 ft. MWM - Water Mark, 10 %of cross sectional area380.7 ft. MWL - Water Level, 5 %of cross sectional area380.7 ft. AMH - Downstream Manhole, Survey Begins - 02 0965

Observation photos (2)

  • Lining Change, Cured in place

    2 ft. - Lining Change, Cured in place

  • Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

Observations (7)

DistanceCodeObservation
0MWM
378.8DAGS
2MLC
0MWL
2DAGS
380.7AMH02 0965
0AMH02 0965

Properties (8)

additional_info
630069121720202
custom_field_three
LIGHT GREASE
custom_field_two
4
customer
1
datetime
2020-12-18T02:32:26-08:00
documentation
PRO PIPE
is_lateral_inspection
false
lining
CIPP